Fire Detection
CONVENTIONAL
CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR
- Low profile design
 - Low current draw
 - Wide operating voltage 8 to 30V
 - Bi-colour LED detector status indicator
 - Programmable sensitivity
 - Addressable feature
 - Advanced maintenance features via remote hand-held test unit
 - Tested & approved to EN54 part 7 (2000)
 
CONVENTIONAL CONTROL PANEL
- Confirms IS 2189 norms.
 - Rugged CRCA sheet with powder coated finish.
 - Modular Construction.
 - Operates on 230 VAC, 24 VDC.
 - Standby Battery backup with build-in charging.
 - Fire / Fault status in unambiguous coloured LED.
 - System On, Main, Standby ON status indication.
 - Low Battery visual warning with audible buzzer tone.
 - Earth fault indication with audible buzzer tone.
 - RS485 for repeater/slave communication (Uses shielded or twisted wire (CAT5E or CAT6)).
 - Relay Outputs for actuators.
 - Lamp test facility.
 - One man walk test facility.
 - Zone Isolation facility with loop voltage cut off.
 - RS 232 Communication for PC Software (Optional)
 - Compatible to all types of conventional detectors.
 
ANALOGUE ADDRESSABLE
Analogue panels
Our range of panels offer a high-specification, analogue fire detection panel is available in a 1, 2 or 4-loop configuration.
Features
- LPCB & BOSEC 3rd party approved to latest:
- EN54-2 1997, A1: 2006
 - EN54-4 1997, A1: 2002 & A2: 2006
 
 - VdS, BOSEC, CNBOP
 - Choice of 1, 2 & 4-loop panel options
 - Large multi functional touch screen
 - Spur tolerant soft addressing
 - Short circuit isolators incorporated into each loop device
 - Up to 200 addresses per loop
 - Multiple panels are fully networked & monitored
 - Optional – printer integration
 
INTELLIGENT SINGLE & 2-LOOP FIRE ALARM CONTROL PANEL
Features & Benefits
- Listed to LPCB standard
 - 2 Loop capacity-477 Addressable Point
 - 8×18 Graphical LCD Display
 - 30 Zone indication including manual intervention & control
 - 3 programmable alarm output
 - Positive Alarm Signal (PAS) Pre-alarm
 - Maintenance report of dirty detector
 - History log 999-events capacity in non-volatile memory
 - Test Facility-Silent Mode
 - Device Start/Stop Mode
 - Device Enable/Disable
 - RS485 Repeater Output (Max. 10)
 - Advanced user friendly programming software including ‘Fuzzy Logic’
 - Optional RS 232 Colour Graphics Software, Printer & Pager Interface
 - Optional RS485 Network Card
 - Optional – printer integration
 
Analogue Sensors
A comprehensive range of analogue sensors are available to operate with the analogue addressable panel range with the following:-
Features
- Built-in short circuit isolators
 - Stylish low profile design
 - 360º viewable LED design
 - Removable detector chamber
 - Drift compensation
 
Addressable Manual Call Points
Manual call points are available as surface & weatherproof versions & approved to EN54-13. All call points have integral short circuit isolators & have a status LED fitted as standard.
Addressable Sounders
Base sounder
The loop-powered integrated sounder & sensor mounting base. It can be used with any analogue sensor or as a standalone sounder with the optional CASC cover plate.
Wall sounder
The range of loop-powered addressable wall sounders offers a highly efficient, low current sounder option. Sounder volume & tone are set at the analogue panel avoiding the need to access each sounder individually to alter settings.
For Technical Specifications, write to us